Descargar Imprimir esta página

TDK-Lambda ZWX Serie Manual De Instrucciones página 15

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 9
1. Model name identification method
ZWX 180 / □
2.Terminal Explanation
2-1.ZWX180, ZWX240 and ZWX300 Terminal Explanation
ZWX180
CN1
① Input Terminal: CN1 (Refer to 2-2.)
② Mounting hole : hole diameter : φ3.5mm
This hole is connected to Protective Earth of CN1.
Must be connected to electrically conductive spacer.
The mounting surface of the spacer should be within Maxφ8mm.
③ Mounting hole : hole diameter : φ3.5mm
This hole is not connected to Protective Earth of CN1.
④ Output Terminal : CN21(+3.3V, +5V and -12V)(Refer to 2-3.)
⑤ Output Terminal : CN31(+3.3V, +5V, +12V, -12V, 5V SB and +3.3Vsense)(Refer to 2-3.)
⑥ Signal Terminal : CN41(PS_ON and PWR_OK)(Refer to 2-3.)
Option (*1)
Rated Output Voltage
Series Name
T3
T2
-2-
TDK-Lambda
ZWX Series
Instruction Manual
(*1)
Blank : Standard type.
/L1 : With chassis model.
/L2 : With chassis model.
/A1 : With chassis and cover model.
/A2 : With chassis and cover model.
(Refer to 6-2. Output Derating for details of
CN41
CN31
CN21
option model.)

Publicidad

loading

Este manual también es adecuado para:

Zwx180Zwx240Zwx300