Micronics
Property
Velocity
Volumetric Flow
Volume
Energy
Power
Acceleration
Table 4- Modbus Measurement Regime vs Units
All other updateable registers can be set by either the unit, or by the
MBM. A simple example are the Totals registers. In normal operation
they are updated and may be read by the MBM, but they may also be
used to rest the totals using the procedure outlined in the ensuing
paragraphs.
Updateable unit functionality includes:
Updating forward and reverse flow totals,
Updating forward and reverse energy totals (reverse energy totals
are not yet implemented),
Updating the lock screen mode,
Updating the damping mode and time, and
Updating the dynamic damping acceleration threshold.
Changes to these registers need to be specifically allowed by the unit.
Changes to totals may be disallowed by setting the "Block remote total
Issue 1.1 March 2022
Metric1
Imperial
m/s
ft/s
l/s
gallons/s
litres
gallons
KWH
BTU
KWH
BTU/sec
2
m/s
ft/sec
Regime
US Imperial
ft/s
US gallons/s
US gallons
BTU
BTU/sec
2
2
ft/sec
Metric2
m/s
3
m
/hr
3
m
KWH
KWH
2
m/s
Page 25