240
0x00F0
0
Unique device identification
Article number
250
0x00FA
0
252
0x00FC
0
Production date
254
0x00FE
0
Detailed product text
Device Localization
24
0x0018
0
Application specific tag
25
0x0019
0
Function tag
Location tag
26
0x001A
0
Equipment identification
242
0x00F2
0
246
0x00F6
0
Geolocation
248
0x00F8
0
NFC web link
Storage location
249
0x00F9
0
253
0x00FD
0
Installation date
Parameter
Device Settings
Commands
2
0x0002
0
System command
Access Control
12
0x000C
0
Device access locks
90
0x005A
0
Extended device access locks
91
0x005B
0
Pin-Code NFC
Pin-Code display
77
0x004D
0
Initial Settings
69
0x0045
0
Drop-Off mode
Outputs function
1
71
0x0047
2
X11 function Pin 2 and Pin 5 (auxiliary voltage)
X12 function Pin 2 and Pin 5 (auxiliary voltage)
3
1
Signal type: SIO outputs of the device
73
0x0049
2
Signal type: SIO inputs of the device
9
bytes
-
ro
14
bytes
-
ro
3
bytes
-
ro
1...64
bytes
-
ro
1...32
bytes
-
rw
1...32
bytes
-
rw
1...32
bytes
-
rw
1...64
bytes
-
rw
1...64
bytes
-
rw
http://...
1...64
bytes
rw
https://...
1...32
bytes
-
rw
1...16
bytes
-
rw
5, 129, 131,
1
byte
165, 167,
wo
168, 169
2
bytes
0, 4
rw
1
byte
0-255
rw
2
bytes
0-999
ro
2
bytes
0-999
rw
1
byte
0-2
rw
1
byte
0-1
rw
1
byte
0-1
rw
1
byte
0-1
rw
1
byte
0-1
rw
1
byte
0-1
rw
-
Unique ID, z.B.: B.:0x00EA 0187F0 3B8B8825
-
Order-number, z.B.: 10.03.01.00648
-
Date code of production (month and year, month is letter coded, z.B.: I19
-
Detailed type description of the device, z.B.: GCP
***
User string to store location or tooling information
***
User string to store location or tooling information
***
User string to store location or tooling information
***
User string to store identification name from schematic
***
User string to store geolocation from handheld device
https://myproduct.schmalz.com/#/
Web link to NFC app (base URL for NFC tag)
***
User string to store storage location
***
User string to store date of installation
0x05 (dec 5): Force upload of parameter data into the master
0x81 (dec 129): Reset application
0x83 (dec 131): Back to box
0xA5 (dec 165): Calibrate vacuum sensor
-
0xA7 (dec 167): Reset erasable counters
0xA8 (dec 168): Reset voltages min/max
0xA9 (dec 169): Reset vacuum min/max
0xAF (dec 175): Setup external valves (Reset and Calibration are executed and SP2/rP2 and
SP1/rP1 Values of GCP written in VSi/LQE)
Bit 0-1: reserved
0
Bit 2: Local parameterization lock (lock menu editing)
BIt 3-15: reserved
Bit 0: NFC write lock
Bit 1: NFC disable
Bit 2: Not used
0
Bit 3: Local user interface locked (manual mode locked)
Bit 4: IO-Link event lock (suppress sending IO-Link events)
Bit 5-7: Not used
0
Pin-Code for NFC write
0
Pin-Code for display
0 = Externally controlled drop-off
0
1 = Internally controlled drop-off – time-dependent
2 = Externally controlled drop-off – time-dependent
0
0 = NO,
0
1 = NC
(only applies if ISDU 88 set to 2)
0
0
0 = PNP,
1 = NPN
0