Descargar Imprimir esta página

schmalz GCPi Manual De Instrucciones página 89

Publicidad

Coding of IO-Link Events
Extended Device Status ID
Extended Device Status Type
(= IO-Link Event Code)
dec
hex
hex
0x0000
0
0x10
6144
0x1800
-
6145
0x1801
0x22
0x8C01
35841
0x22
20736
0x5100
0x42
20752
0x5110
0x42
20754
0x5112
0x42
6162
0x1812
0x42
6156
0x180C
0x22
6157
0x180D
0x22
0x4000
16384
0x22
6152
0x1808
0x22
0x1809
6153
0x22
6154
0x180A
0x22
6155
0x180B
0x22
0x1811
6161
0x82
IO-Link
Meaning
Event Type
Everything OK
(no IOL event)
(IOL event only)
Notification
Warning
Notification
Warning
Warning
Critical condition
Error
Critical condition
Warning
Critical condition
Warning
Critical condition
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Defect/fault
Error
Event name
Everything OK
Vacuum calibration OK
Vacuum calibration failed
Simulation active
General power supply fault
Primary supply voltage over-run
General power supply fault
General power supply fault
CM: Primary supply voltage out of optimal range
CM: Secondary supply voltage out of optimal range
Temperature out of optimal range
CM: Evacuation time above limit
CM: leakage rate above limit
CM: SP1 not reached
CM: Free flow vacuum too high
Data corruption
Remark
Device is working optimally
Calibration offset 0 set successfully
Sensor value too high or too low, offset not changed
Manual mode is active
Primary supply voltage (US) too low
Primary supply voltage (US) too high
Auxiliary supply voltage (UA) too low
Auxiliary supply voltage (UA) too high
Condition Monitoring: primary supply voltage US outside of operating range
Condition Monitoring: secondary supply voltage out of optimal range
Temperature overrun
Condition monitoring: evacuation time t1 is above limit [t-1]
Condition Monitoring: leakage rate is above limit [-L-]
Condition monitoring: vacuum level SP1 was never reached during
suction cycle
Condition monitoring: free flow vacuum above SP2
Internal error, user data corrupted

Publicidad