Descargar Imprimir esta página

Ega Master 79422 Manual De Instrucciones página 32

Perforadora

Publicidad

Idiomas disponibles

Idiomas disponibles

do not have any restrictions or kinks,
are designed for a minimum operating pressure of 6 bar,
are replaced regularly at preventative maintenance,
have an oil resistant inner surface and an abrasion-resistant outer surface,
are proved and specified to be non-conductive when being used next to electric conductors.
Always use hoses, lubricating oil and antifreeze lubricants, which meet the local safety
requirements for use in areas exposed to explosion hazards.
Connecting the air supply to the pneumatic core drill
Remove the locking cap from the air connection 3. Connect the pneumatic hose (not
contained in the scope of delivery).
General
Assembly and disassembly tools are part of the full scope as well:
- Wrench AF 32
- Wrench AF 41
Changing of drill bits
Disconnect the machine from the pneumatic supply.
Use a single-head wrench AF 41 and a wrench AF 32 to unscrew the drill bit.
Screw on manually the new drill bit.
Drilling with a drill rig (fig. 5)
Fix the rig at the required point.
(Fixing see operating instruction of the drill rig.)
32
Exhaust
Air inlet
Fig.2
STARTUP
Stop
Start

Publicidad