Passenger Headlight
Bracket for Gasket
M12 Screw
Post Bracket
M6 Washer
M6 Lockwasher
M6 Screw
Friction Washer
Post Base
Gasket for Base
M12 Washer
M12 Lockwasher
M12 Nut
3. Route wires between the power source and the control system. Install user-supplied fuses and fuse
holders as close as possible to the power source. Refer to Table 2 for minimum wire gauges and fuse
ratings for each wire/function on the plow headlight.
HIGH CURRENT DEVICE: A plow headlight is a high current system. In order for the system to
function properly, separate negative (-) and positive (+) connections must be made. All negative
connections should be connected to the negative battery terminal, and appropriate fuses should
be installed on the positive connections as close to the battery terminal as possible. Ensure that
all wires and fuses are rated correctly to handle the system amperage requirements.
Wire Color
Red
Yellow
Green
Grey
Black
CHECK WIRING POLARITY: This device is only intended to have a common ground and be
switched on the positive voltage connections. Some vehicles are wired to have a common
positive voltage and be switched on the ground connections. If this device is connected in
reverse polarity, permanent damage may occur and render the device inoperable.
ICON Series ICSSPL-P Snow Plow Headlight
Federal Signal worktruck.fedsig.com
Installing the ICON Series ICSSPL-P Snow Plow Headlight
Figure 1 Exploded View of Headlight Mounting
Table 2 Wiring and Functions
Wire Function
High Beam (+)
Low Beam (+)
Turn Signal Lights (+)
Parking Light (+)
Ground (-)
Recommended
Recommended
Minimum Gauge
Fuse at 12 Vdc
16 AWG
10 A
18 AWG
5 A
22 AWG
1 A
22 AWG
1 A
16 AWG
-