Overload Protector - Sears Kenmore 116.31140 Manual De Uso Y Cuidado

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

BY-PASS VALVE
This vacuum cleaner has a By-Pass Valve
which prevents motor overheating and
damage. The valve opens to provide
cooling air when a clog prevents normal
air flow to the vacuum cleaner suction
motor. You will notice a change of sound
as air rushes through the valve opening.
!
J-By-pass
Valve
To correct problem, install a new dust
bag. If using attachments, adjust suction
control to allow for greater air flow.
NOTE: The By-Pass Valve may open when
using attachments
or when cleaning new
carpet due to reduced airflow caused by
the attachments
themselves or by new
carpet lint filling the dust bag quickly.
NOTE:
Do not block By-Pass Valve.
AGITATOR
OVERLOAD
PROTECTOR
The agitator
has built-in
protection
against
motor
damage
should
the
agitator
jam. If the agitator
slows down
or stops, the agitator
overload
protector
shuts off the agitator
motors.
The vacuum
cleaner
suction
motor
will continue
to run.
To correct problem: Turn off and unplug
vacuum cleaner, remove obstruction, then
press OVERLOAD PROTECTOR RESET.
NOTE: Once the agitator motor shuts
down, clear jam from agitator and
wait a minimum of 20 seconds before
resetting overload protector.
If the problem
persists, have the vacuum
cleaner
serviced
by a Sears or other
qualified
technician.