User and installation manual HNS-T1
Electrical connections
The sauna heater must be connected to the mains by a qualified electrician and in compliance with current
regulations. The steam generator is connected with a semi-permanent connection. Use H07RN-F (60245 IEC 66) or
a corresponding type cables
Output
kW
3.4
4.7
6.0
7.7
9.5
12.0
14.0
Steam generator's heating elements
Teho
Power
Leistung
3.0
1,000W / SEPD 131
3.4
1,150W / SEPD 97
4.7
1,567W / SEPD 98
6
2,000W / SEPD 99
7.7
2,567W / SEPD 100
9.5
5,250W / SEPD 116
12
4,250W / SEPD 119
14
5,250W / SEPD 116
Connection diagrams
Electrical connections
3,4 - 14 kW 400V - 415V 3N~
G
A
B
C
D E
F
L1 L2 L3 N
All manuals and user guides at all-guides.com
Generator con-
Fuse
nection cable
H07RN-F / 60245
IEC 66
2
mm
400V-415V 3N~
A
5 x 1.5
3 x 10
5 x 1.5
3 x 10
5 x 1.5
3 x 10
5 x 2.5
3 x 16
5 x 2.5
3 x 16
5 x 6
3 x 25
5 x 6
3 x 25
Vastus / Element / Heizstäbe 230V
1
2
1,000W / SEPD 131
1,150W / SEPD 97
1,567W / SEPD 98
2,000W / SEPD 99
2,567W / SEPD 100
3,500W / SEPD 115
3,500W / SEPD 115
3,500W / SEPD 115
3,4 - 14 kW 230 V 3~
S
G
A
B
C
L1 L2 L3
Generator con-
Fuse
nection cable
H07RN-F / 60245
IEC 66
2
mm
230V 3~
A
4 x 1.5
3 x 10
4 x 2.5
3 x 16
4 x 2.5
3 x 16
4 x 6
3 x 25
4 x 6
3 x 25
4 x 10
3 x 35
4 x 10
3 x 50
3
1,000W / SEPD 131
1,150W / SEPD 97
1,567W / SEPD 98
2,000W / SEPD 99
2,567W / SEPD 100
5,250W / SEPD 116
4,250W / SEPD 119
5,250W / SEPD 116
3,4 - 7,7 kW 200V - 240V 1N~ / 2~
D E
F
S
G
Generator connec-
Fuse
tion cable
H07RN-F /
60245 IEC 66
2
mm
230V-240V 1N~/2~
A
3 x 2.5
16
3 x 6.0
25
3 x 6.0
25
3 x 10
35
------
------
------
------
------
------
A
B
C
D E
F
S
200V - 240V~