User manual
ArcForce
Ampere (unit)
Time (unit)
Percentage (unit)
Volt (unit)
Hertz (unit)
KiloJoules (unit)
LOCK
JOB
TIG process
MMA process
Standard mode
Pulse Mode
Spot Mode
Tack Mode
Multi Spot Mode
Multi Tack Mode
HF ignition
LIFT ignition
Touch HF ignition
2T
4T
4T LOG
Gas purge
THUMBWHEEL NAVIGATION
Rotating the thumbwheel allows
- adjustment to the welding current
- to change a parameter of the welding cycle
Pressing the thumbwheel allows
- access to the welding cycle by selecting the first parameter
- access to the parameter settings and confirm the modification
TIG (GTAW) WELDING MODE
INSTALLATION AND GUIDANCE
• DC TIG welding requires a protective gas shield (Argon).
• Connect the earth clamp to the positive (+) plug connector. Connect the torch power cable to the
negative (-) socket, along with the torch button(s) and gas connector(s).
• Ensure that the torch is properly fitted and that the consumables (clamps, collet bodies, diffusers and nozzles) are not worn out.
• The electrode is determined by the welding current of the TIG process.
30
Translation of the original
instructions
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
+
x
x
+
x
x
+
x
x
x
+
x
Overcurrent delivered during welding (-10 to +10).
Amperage unit for current adjustment and welding current display.
The unit of seconds for timing settings or the display of welding duration.
Unit of percentage for proportional settings.
Voltage unit for the display of the welding voltage.
Hertz unit for frequency settings.
Unit in KiloJoules for the welding energy display.
Lock/unlock button (press for 3 seconds).
Button to access the JOB menu (save and recall a program).
This button also returns to the previous screen.
Arc welding with a non-melting tungsten electrode under protective gas shiel-
ding.
Arc welding with a consumable coated electrode
Smooth current
Pulsed current
Smooth tacks
Pulse + smooth tacking
Repeated smooth tacking
Repeated pulsed tacking
High-frequency ignition
Ignition with contact
Time-delayed high-frequency ignition
2T trigger mode.
4T trigger mode.
4T LOG trigger mode.
Gas purge activation button for the torch.
TITAN 231 DC FV