DCX Next / DCX 13 Next
2. Technical specifications
Model
Energy efficiency class
Rated capacity / rated current
EN
Chosen capacity / current
Nominal voltage
Electrical connection
Min. required cable size
Hot water (l/min)
max. at ∆t = 28 K
max. at ∆t = 38 K
Rated volume
Rated pressure
Connecting type
Heating system
@ 15 °C:
Required specific water resistance
Specific electrical conductivity
Inlet temperature
Flow rate to switch on – max. flow
rate
Pressure loss
Temperature range
Water connection
Weight (when filled with water)
VDE class of protection
Type of protection / safety
* ) The declaration complies with the EU regulation No 812/2013.
1) Maximum applicable cable size is 10 mm
2) Mixed water
3) Flow rate limited to achieve optimum temperature rise
4) Without flow regulator
3. Dimensions
468 363
DCX 13 Next
11 kW..13.5 kW (16 A..20 A)
11 kW /
9.9 kW
16 A
/ 15 A
400 V 380 V 400 V 380 V 400 V 380 V 400 V 380 V 400 V 380 V 400 V 380 V
1.5 mm
1)
2
5.6
5.0
2)
4.1
3.7
1.5 l/min – 5.0
at electrical connection from above
2
170
56
100
13.5 kW
12.2 kW
18 kW /
16.2 kW
/ 20 A
/ 19 A
26 A
/ 25 A
3~ / PE AC
2.5 mm
4.0 mm
2
2
6.9
6.2
9.2
8.3
2)
2)
2)
5.1
4.6
6.8
6.1
2)
0.4 l
1.0 MPa (10 bar)
pressure-resistant / pressureless
Bare wire heating system IES
≥ 1100 Ωcm
≤ 90 mS/m
≤ 30 °C
3)
0.08 bar at 1.5 l/min
35 °C / 38 °C / 42 °C / 48 °C / 55 °C
G ½ inch
4.2 kg
Dimensions in mm
239
96
24
DCX Next
A *
)
18 kW..27 kW (26 A..39 A)
21 kW /
19 kW /
24 kW /
21.7 kW
30 A
29 A
35 A
/ 33 A
4.0 mm
6.0 mm
2
2
10.7
9.7
12.3
11.1
2)
2)
2)
2)
7.9
7.2
9.0
8.2
2)
®
1.5 l/min – 8.0
3)
1.3 bar at 9.0 l/min
4)
I
IP25
27 kW /
24.4 kW
39 A
/ 37 A
6.0 mm
2
13.8
12.5
2)
2)
2)
10.2
9.2
2)
2)
2)