Descargar Imprimir esta página

PNI GreenHouse SC1800C PRO Manual De Usuario página 21

Inversor solar

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 113
Program Description
00
Exit settings mode
Output source
01
priority selection
Selectable options
21
Solar
energy
energy
to
ers as a priority source.
If the battery voltage is
higher than the level set in
program 21 for 5 minutes,
the inverter will return to
battery mode and the con-
sumers will be powered si-
multaneously from both the
solar source and the battery.
If the battery voltage drops
to the level set in program
20, the inverter will return to
bypass mode, the consumers
will be powered only from
the public power grid while
the solar source will charge
the battery.
Solar energy provides energy
to consumers as a priority
source.
If the battery voltage is
higher than the level set in
program 21 for 5 minutes,
and if the solar energy
was available during this 5
minutes, the inverter will
switch to battery mode, the
solar source and the battery
will supply energy to the
consumers at the same time.
provides
consum-
User manual

Publicidad

loading

Este manual también es adecuado para:

Pni-sc1800pro