through is in material quality EN 1.4016. Take necessary precautions to avoid galvanic corrosions.
Fasten roof feed-through flange with appropriate stainless-steel screws.
INLET AIR
An inlet air hose is included in the installation box. Use
an 83 mm hole saw for implementation in flooring.
An optional floor nozzle is available for double floors.
Consider air supply into double floor compartment for
sufficient air flow.
If the wheel arch or other obstructions prevent the hose
from going directly down, it can be bypassed, but make
sure the hose is routed with gentle bends and as short a
stretch as possible, maximum hose length 120 cm. Finish
with floor nozzle under floor exterior. The hose may be
insulated, if desired.
An air grate can be used in both floor and wall, but make sure you have a minimum 50 cm² light
opening and that you protect against water intrusion. Please note that floor intake is preferred
instead of wall intake. If the toilet in large parts of the year is used in cool climates that experience
extreme cold for extended periods, condensation may form on the outside of the toilet. It may be
advantageous to preheat the air in. This can be done using a radiator connected to the heating system
that preheats the air.
GAS INSTALLATION
NOTICE!
Please note that a sticker is delivered with the toilet for marking
of the gas shut-off valve and this sticker is mandatory in some countries.
Please be aware that regulations regarding gas installations in vehicles vary from country to
country. The installation may require certified personnel in order to be approved. Be sure to
research the local regulations where you live and adhere to these before installation.
The gas is supplied through an 8 mm pipe directly to the toilet with an angled compression fitting on
top of the Build-in module. No adjustment of fitting is allowed. The toilet is designed to run on propane.
If you know that you frequent areas with low quality propane, a filter should be considered. A separate
gas shut-off valve is required when connecting to an existing gas supply line.
This will aid trouble shooting and allow operation of other appliances in case the toilet is dismounted.
The connector is a brass compression coupling which takes ø8 pipe. Be sure to clamp the pipe close to
the fitting to avoid stress fatigue in the pipe.
INSPECTION HATCH
There must be access to the top of the Build-in module
for easy access to connections. This allows for annual
inspection and leak testing of the gas connection.
CONTROL PANEL
Locate the desired placement of the control panel.
Create an opening for the signal cable and route the
cable out here. The signal cable is a flat cable with
approx. 20 mm width. Connect the signal cable together
with the control cable and fasten the control panel. The
signal cable can be connected in two ways, but only
one way is correct. If you get a red light, and not a green,
reconnect signal cable the opposite way. The signal cable
is approx. 150 cm long.