ENGLISH
Operating and installation
instructions
Please check that your unit is in per-
fect conditions when unpackaging it,
as any defect of manufacturing is co-
vered by the S&P guarantee.
INSTALLATION
Important: be sure to switch off the
power supply before installing and
making the electrical connections.
The EDM-80 L is particularly suitable
for ventilation of bathrooms, toilets,
showers, etc. either discharging to
outside, or through individual ducts
and ducting systems, and has been
specially designed for fi tting in the
same location asa standard builders
wall vent.
Before installation, remove the front
grille by loosening the fi xing screw
(Fig. 2).
A circular hole approximately 100
mmØ diameter must be made in the
wall or ceiling and the fan spigot in-
serted into the hole, fi xing the fan ca-
sing by means of the wall plugs and
screws supplied. Ensure that there
are no obstructions to the airfl ow is
discharge is to outside or into a com-
munal ventilation system.
When individual outlet ducting is
used, standard 100 mm Ø diameter
should be used.
WIRING
This appliance is conside-
red to be suitable for use
in countries having a warm
damp equable climate as
specifi ed in IEC 60721-2-1.
It may also be used in other
countries.
The EDM-80 L is suitable for connec-
tion toa single phase supply at the
voltage and frecuency indicated on
the rating plate. This appliance has
double (Class II) electrical insulation
and therefore does not require ear-
thing.
Connection terminals are situated
under the front cover.
There should bea double pole isola-
ting switch in the installation (witha
contacting opening of at least 3 mm).
For surface wiring pass the cable
through cable gland as shown in Fig.
5b (not as Fig. 5a) then under the ca-
ble anchorage secure.
For recessed wiring, open membrane
in fan back plate, pass cable through
and secure with cable anchorage.