Finish operation
Press the on/off operation button to switch the de-
vice off.
Storing the appliance
Stow away the mains cable and accessory at the
machine. Store the appliance in a dry room.
Care and maintenance
Regularly dry clean the machine casing so that no dust
can collect on it.
First remove the mains plug before doing any job
on the device
Wipe off the device with a dry soft cloth.
Wipe the filter covers and air outlet with a dry soft
cloth.
Filter replacement
If the filter change indicator lights up:
Illustration
Open and remove the filter covers with the handles.
Unlock and remove the pre-filter.
Clean pre-filter.
Remove the fine filter at the label from the device.
Note
–
Both pre-filters always have to be cleaned.
–
The pre-filter is washable.
–
Both fine filters always have to be renewed.
Illustration
Remove packaging from the filters.
Insert the fine filter in the device. The label should
be visible from the outside.
Insert the guide noses of the pre-filter in the lower
recesses.
Carefully lock the pre-filter at the top and ensure
correct positioning at the sides.
Insert the guide noses of the filter cover in the lower
recesses.
Close the filter cover from above.
Filter type
Part number
Universal filter
2.863-246.0
Smog filter
2.863-247.0
TVOC filter
2.863-248.0
Pet Pure filter
2.863-249.0
Mains voltage
Frequency
Intake performance
Level 1
Level 2
Level 3
Dimensions
Depth
Width
Height
Area
8
Special accessories
Application
for air pollution, especially for fine dust (PM2.5), formaldehyde
for air pollution, especially for fine dust (PM2.5)
For volatile organic compounds (TVOC), especially for formaldehyde
For hair and volatile organic compounds (TVOC), especially for ammonia
Technical specifications
220 - 240
V
50/60
Hz
11
W
26
W
56
W
380
mm
380
mm
713
mm
42 - 72
m
2
The air quality sensor should be cleaned every two
months in order ensure ideal functioning. If the device is
to be operated in a dusty environment, it should be
cleaned more often.
Note
If the humidity is very high, condensation may form on
the air quality sensor. Due to this, the air quality LED
display may indicate poor air quality, even if it is good. If
this occurs, clean the air quality sensor or select manual
mode.
Illustration
Press the air quality sensor cover in the middle and
open it.
Clean the air quality sensor and the air openings
with a damp cotton swab.
Dry the air quality sensor with a dry cotton swab.
Press the air quality sensor cover in the middle and
close it.
Troubleshooting
Appliance is not running
Plug in the power cord.
Close the filter cover.
Air quality sensor display lights up red
Clean the air quality sensor.
Air quality does not improve
Make sure that all filters have been inserted cor-
rectly.
Airflow from the air outlet is no longer so
Clean pre-filter.
Weight (without accesso-
ries)
Sound power level L
Subject to technical modifications!
– 8
EN
Air quality sensor
continuously.
strong
11,2
62
WA
kg
dB(A)