PSU67-1P-1M-2M5-24150-IOL-F
EN
Quick Start Guide
PSU67-1P-1M-2M5-24150-IOL-F
Additional documents
The following additional documents are available online at www.turck.com:
Data sheet
Declaration of conformity
For your safety
Intended use
The power supply PSU67-1P-1M-2M5-24150-IOL-F is a stand-alone switching
power supply for single-phase indoor networks with IO-Link interface.
The device may only be used as described in these instructions. Any other use
is not in accordance with the intended use. Turck accepts no liability for any
resulting damage.
General safety instructions
The device must only be mounted, installed, operated and maintained by
trained and qualified personnel.
The device is a "Class of Protection I" equipment according to IEC 61140.
The device is designed for pollution degree 3 areas in controlled environ-
ments.
Only use the device in applications up to overvoltage category III according
to IEC 60664-1. From an altitude of 2000 m, use only in applications up to
overvoltage category II.
Only use the device with additional protective devices in the area of per-
sonal and machine protection.
Operate the device exclusively within the technical specifications in order
not to impair the protective function of the device.
Do not connect the negative potential of any output externally to PE.
Only use the device with a proper PE (Protective Earth) connection.
Product description
Device overview
S. fig. 2: dimensions, s. fig. 3: Block diagram
Functions and operating modes
The power supply provides a stabilized and galvanically separated PELV/ES1
output voltage at the four outputs OUT1...OUT4. The negative potential of
the outputs is permanently connected to PE in the device. The outputs are
electronically protected against open-circuit, overload and short-circuit and
can supply any type of loads, including unlimited inductive and capacitive
loads.
The device can be connected to an IO-Link master via an IO-Link interface
V1.1.
The device is equipped with an over-temperature protection. In case of a
over temperature, the device shuts down and starts automatically again
after cooling off. The outputs return to the state they had before being
switched off.
In case of an internal defect, a redundant circuit limits the maximum output
voltage to 32.5 V. The outputs are shut down and restart automatically if the
defect is eliminated.
Installation
General installation instructions
The unit is suitable for use at altitudes up to 5000 m (16400 ft). Above 2000
m (6560 ft), the output current and overvoltage category must be reduced.
The device is suitable for use at TN, TT and IT networks.
The voltage between the input terminals and the PE potential must not
exceed 264 VAC.
The device uses convection cooling. An external fan is not necessary.
Special mounting instructions
CAUTION
Sharp edges on the back of the device
Risk of injury
Mount the devices on a sufficiently large, even surface so that all sharp
edges are covered.
Mount the device vertically with the connection level facing downwards
on a flat surface using two screws each (M4 or UNC 8-32) at the upper and
lower mounting holes.
Other mounting orientations: reduce the output current.
Do not obstruct airflow. Do not cover ventilation fins.
Observe the minimum installation clearances: 30 mm on top and bottom,
10 mm on the front and 10 mm left and right side.
Connecting
Connect the device according to "Wiring diagrams".
Mating connectors
Input voltage (XD1): 7/8" female connector, 3-pin
IO-Link (X0): M12 female connector, A-coded, 5-pin
Output voltage (XD2, XD3): 7/8" male connector, 5-pin
Appropriate accessories can be found at www.turck.com. The accessories
are not part of the scope of delivery.
Do not apply return voltages from the load to the output higher than 35 V.
Do not connect outputs or devices in parallel.
The device is designed, tested and approved for branch circuits up to 20 A
(UL) and 32 A (IEC) without additional protection device.
If an external fuse is used, use B or C characteristic circuit breakers with at
least 6 A to avoid a nuisance tripping of the circuit breaker.
DC supply voltages above 150 VDC: Use an external circuit breaker (6 A
with B or C characteristic).
PSU67-1P-1M-2M5-24150-IOL-F
IP67 Power Supply
Quick Start Guide
Doc. no. 100034421
Additional
information see
turck.com
38
182 [7.17]
20
[1.50]
168.2 [6.62]
[0.79]
163.7 [6.45]
107
[4.21]
4.5
[0.18]
7/8-16UN
7/8-16UN
M12 × 1
7/8-16UN
mm [Inch]
Input
L
Fuse
2
N
Filter
3
+
PFC
Power
E-Fuse
PE
PE
Recti er
Converter
Control
XD1
Inrush Current
Limiter
Temperature
Output
Output
Shutdown
OVP
Power
Manager
IO-Link
Control
Trip Delay/s
2 3 4 5 6
8
10
[A]
10
1
0.1
0
0
5
10
15
20
© Hans Turck GmbH & Co. KG | 100034421 2022-10
59 [2.32]
56.3 [2.22]
183
199.3
[7.21]
[7.84]
Output
+
Out1
4
2
FE
Out2
+
5
1
XD2
+
Out3
4
2
FE
Out4
+
5
1
XD3
LED bar
Status
Set
1
V+
3
V-
4
Data
X0
25
I
/A
(typ.)
Out

Publicidad