Appliance stops
cooling after a
running cycle of 50
minutes.
TECHNICAL DATA
Notice: Operation temperature range:
Dry bulb temperature / Wet bulb temperature(℃)
Below data for your operating reference
Model
Rated voltage
Rated frequency
Rated input
Rated current
Cooling capacity
Moisture removal (L/H)
Air flow
Max. transmitting power
Frequency range
ERP INFORMATION
Trademark
Model identification
Sound power (cooling)
Name of refrigerant
Rated power input for cooling (kW)
Rated energy efficiency ratio
GWP (kgCO
eq)
2
Energy efficiency class
Energy consumption for double ducts appliances (kWh/h)
Energy consumption for single duct appliances (kWh/h)
Power consumption in thermostat-off mode (W)
Power consumption in stand-by mode (W)
Cooling capacity
Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP)
would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to 3. This means that if 1 kg of this refrigerant
fluid would be leaked to the atmosphere, the impact on global warming would be 3 times higher than 1 kg
of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble
the product yourself and always ask a professional.
#Energy consumption 1.0 kWh for model PAC-127111.1
The actual energy consumption depends on how the device is used and where it is located.
When the ambient room temperature
drops to 21⁰C or below for 50 minutes
during cooling mode, the appliance will
be stopped for 5 minutes by the default
programme.
PAC-127111.1
220-240V
50Hz
1000W
4.5A
2500W (9000Btu/h)
1.0
230m³/h
20 dBm
2400 - 2484 MHz
No action required. This is to avoid the
internal copper cooling pipes from
freezing. The appliance will resume
again after 5 minutes and this cycling
process will be repeated continuously.
Maximum cooling
35/24
Value
Emerio
PAC-127111.1
≦65dB(A)
R290 (0.16kg)
1.0
2.6
3
A
N.A
1.0
N.A
2.0W
2500W
in
60 minutes of use under standard test conditions.
- 14 -
Minimum cooling
18/12

Publicidad