• Spreader speed indicator flashes and trouble indicator turns on.
• The 3 application indicators flash and trouble indicator turns on.
• Battery charge indicator flashes.
• Battery charge indicator flashes once, trouble indicator turns on, and the
equipment turns off.
• Battery charge indicator flashes and trouble indicator turns on.
For further information on how to indentify the causes and correct them, refer to
item "12.1. Joystick panel troubleshooting" on page 27.
Trigger
Press the trigger to release the dosage.
10. Operating the Equipment
10.1. Filling the tank
• Remove the tank lid.
• Fit the strainer and pour the product to be used in the application.
OBS.: Using the strainer prevents inputs stuck together or other impurities from
impairing the equipment performance. Use inputs approved by regulatory au-
thorities and free from excessive moisture.
Strainer
• Remove the strainer, put the lid back on, and tighten it correctly to avoid waste
and prevent humidity from entering.
10.2. Adjusting the dosage
To adjust the dosage, Jacto GB-18 has 3 levels of flow opening: a maximum
opening of approximately 70 g/s, a medium opening of approximately 90 g/s,
and a minimum opening of approximately 45 g/s*. The equipment is set at the
factory at maximum dosage application opening. To select the required flow,
check the steps below.
*OBS.: Data based on urea application. If the operator walks at a speed of approx-
imately 3 km/h, these openings allow applications of 60 g/m a 200 g/m. These
values can range according to density, format, size and condition of the input
used. For more precise data, the flow has to be calculated wiht the help of a scale
and a stopwatch.
• Identify the dosage regulating pin located next to the 45° duct.
Lid
Dosage regulating pin
• Inside the same place, identify the two dosage flow regulating orifices.The left
orifice (lower) selects the minimum opening. Whereas the right orifice (upper)
selects the medium opening.
• To make some adjustments, just fit the dosage regulating pin in the orifice,
and turn it counterclockwise. To remove it, just turn the pin clockwise. By do-
ing so, the flow opening will go back to maximum.
10.3. Calibrating the dosage
To calibrate the dosage, first fill Jacto GB-18 tank with the input that will be used,
adjust the flow thorugh the dosage regulating pin, use a glass to collect it and a
precision scale. After that:
OBS¹.: For up to 50-g dosage, the minimum flow opening is recomended; for 50-g
to 150-g, the medium opening is recommended, and over 150-g, the maximum
one is recommended.
OBS².: In case Jacto AG-95 Electric Spreader is being used, remove it before-
calibrating.
OBS³.: Calibrate with the spreading duct at the work position, that is, as vertical
as possible. If necessary, remove one or two extender ducts.
• Tare the weight of the collection glass on the scale.
• Press and hold the function selector button until the calibration indicator light
turns on.
Calibration indicator
Function selector button
• Once dosage is defined, press the trigger to apply inside the collection glass.
• Check if the weight of the applied dosage is close to the one desired
• In case the weight is below the desired standard, press the trigger for more
time. In case the weight is above the desired standard, press the trigger for
less time.
Left orifice
Right orifice
(minimum opening)
(medium opening)
Trigger