7.2.2
Checking shielding ring
1. Check the contact surface of the shielding ring.
Result 1 / 2
The contact surface is free of foreign matter.
▶ The shielding ring can remain in use.
Result 2 / 2
Spatter is present on the contact surface, or the contact surface is no longer complete or damaged in
some other way.
▶ The shielding ring cannot remain in use.
2. Replace the shielding ring.
Materials
Shielding ring
XSR F3
7.2.3
Checking brass ring
▶ Check the outflow openings for the inert gas in the brass ring.
Result 1 / 2
The outflow openings are free of foreign matter.
▶ The product can remain in use.
Result 2 / 2
The outflow openings are clogged/blocked.
▶ Have the product repaired by Hilti Service.
8
Transport and storage of cordless tools and batteries
Transport
▶ Do not send the product through the mail. Consult your shipper for instructions on how to ship the
product. Comply with the locally applicable regulations for transporting batteries and pressurized
inert-gas cans.
▶ Do not transport the product by crane.
▶ Prior to each use and before and after lengthy transport, always check all visible parts for signs of
damage and make sure that all the controls are in full working order.
Storage
▶ Store the product in a cool and dry place. Comply with the temperature limits stated in the technical
data.
▶ Fully charge the product in preparation for lengthy storage and recharge the product every 6 months at
the latest.
▶ Do not store the product with the charger connected. After recharging, always disconnect the product
from the charger.
▶ Never leave the product in direct sunlight, on sources of heat, or behind glass.
▶ Do not store the product in a potentially explosive environment.
▶ Store the product where it cannot be accessed by children or unauthorized persons.
▶ To prevent damage to the inert-gas can, comply with the safety data sheet of the inert-gas can.
▶ Prior to each use and before and after lengthy storage, always check all visible parts for signs of damage
and make sure that all the controls are in full working order.
9
Troubleshooting
If the trouble you are experiencing is not listed in this table or you are unable to remedy the problem by
yourself, please contact Hilti Service.
9.1
Troubleshooting table
Trouble or fault
Inert-gas can is damaged
*2302409*
16
17
Possible cause
Mechanical damage to the inert-
gas can
2302409
Action to be taken
▶ Dispose of the inert-gas can
in accordance with your local
regulations.
English
15