Descargar Imprimir esta página

WERTHER INTERNATIONAL 210I/42 Manual De Instrucciones página 16

Publicidad

Fig.7-Abb.7
14
All manuals and user guides at all-guides.com
CAP.2
SPECIFICHE TECNICHE
PORTATA: ................................................4200 Kg (41202 N)
Alt. max. sollevamento auto ......................2011 mm
Alt. min. supporti sollevamento ................. 95 mm
Tempo di salita ......................................... 43 sec
Tempo di discesa ......................................
43 sec
Peso totale del sollevatore ........................circa 715 Kg
Rumorosità ................................................<70dB(A)/1m
Temperatura di funzionamento : ...............-10°C / +50°C
Pressione di lavoro....................................195 bar
Ambiente di lavoro: locale chiuso.
Fig.7 Dimensioni ed ingombri
MOTORE ELETTRICO:
Trifase
Potenza del motore
2,2 kw
2.2 kw
elettrico
Tensione
230-400V trif.+/-5%
230V mono+/-5%
Frequenza
50 HZ
50 HZ
Assorbimento
230V:10,7A
15.9A
400V:6,2A
N° poli
4
4
Velocità
1400RPM
1380RPM
Forma costruttiva
B14
B14
Classe di isolamento
IP54
IP54
Tipo
90L4
90L4
Il collegamento del motore deve essere eseguito riferendosi agli schemi
elettrici allegati.
Il senso di rotazione del motore deve coincidere con quello indicato dal-
la freccia sulla pompa; in caso contrario modificare i collegamenti elet-
trici (Vedere Cap.4 INSTALLAZIONE- Allacciamento impianto elettrico).
CHAPTER. 2
SPECIFICATIONS
CAPACITY: ...............................................4200 Kg (41202 N)
Car max. lifting height................................2011 mm
Lift min. stand height ................................. 95 mm
Rise time .......................................................43 sec.
Descent time .............................................
Total lift weight ..........................................about 715 Kg
Noise .........................................................<70dB(A)/1m
Operating temperature: .............................-10°C/+50°C
Working pressure ......................................195 bar
Work environment: closed room.
Fig.7
Dimensions and overall clearances
ELECTRIC MOTOR:
Monofase
Electric motor power ra-
ting
Voltage
Frequency
Absorption
N° of poles
Speed
Construction size
Insulation class
Type
The motor must be connected with reference to the attached
wiring diagrams.
The motor rotation direction must be the same as shown by the arrow
on the pump; if not, modify the electrical connections (see Ch.4, IN-
STALLATION-electric plant connection)
TECHNICAL
43 sec.
Three-phase
Singlephase
2,2 KW
2,2 KW
230-400V 3ph.+/- 5%
230V 1ph. +/- 5%
50 Hz
50 Hz
230V:10,7A
15.9A
400V: 6,2A
4
4
1400 RPM
1380 RPM
B14
B14
IP54
IP54
90L4
90L4

Publicidad

loading