6. OPERATING INSTRUCTIONS
NOTE: Read and understand all Warning and Caution statements in this operation manual prior to
using this meter. Set the rotary switch to the OFF position when the meter is not in use.
Current Measurement
• Disconnect the test leads before making clamp measurements
• To avoid electrical shock and/or damage to the meter, do not attempt to take any voltage
measurement that might exceed 600V.
o Set the rotary switch to proper current range, select the correct range based on measurement
o Press the clamp opening trigger to open the jaws and fully enclose one conducting wire
o Read the measured current value in the LCD display
o If display shows "OL", means overload, should select the higher range of measurements
o To shift the AC or DC current by pressing SEL button
DC Voltage Measurement
• The max. input DC voltage is 600V DC, to avoid electrical shock and/or damage the meter, do
not attempt to take any voltage measurement that might exceed 600V DC.
o Set the rotary switch to the V
o Insert the black test lead banana plug into COM jack, insert the red test lead banana plug into
INPUT jack.
o Touch the black test probe tip to the negative side of the circuit; touch the red test lead probe
tip to the positive side of circuit.
o Read the voltage value in the display.
NOTE:
• Unstable display may occur, especially at the low voltage range measurement (like 200mV
range), even no test leads insert at input terminals, and it is the normal situation and not
influences the accuracy.
AC Voltage Measurement
• The max. input DC voltage is 600V DC, to avoid electrical shock and/or damage the meter, do
not attempt to take any voltage measurement that might exceed 600V DC.
o Set the function switch to the V~ position.
o Insert the black test lead banana plug into COM jack, insert the red test lead banana plug into
INPUT jack.
o Touch the black test probe tip to the negative side of the circuit; touch the red test lead probe
tip to the positive side of circuit.
o Read the voltage value in the display.
NOTE:
• Unstable display may occur, especially at the low voltage range measurement (like 2V range),
even no test leads insert at input terminals, and it is the normal situation and not influences
the accuracy.
position.