Assembly:
-
Remove sealing plug on the right side of the pump
(see picture).
-
Screw angle plug 5 into the threaded hole of the pump.
-
Connect return hose 4 to the reservoir by means of the
angle plug connection 3, the adapter 2 and / or 1.
-
It is absolutely necessary to lead the return hose 4 back
into the reservoir and securely connect it with the tank.
Safety instructions:
Failure to comply with the safety instructions can endanger persons as well as the
environment and the system. Failure to comply with the safety instructions may result in
the loss of any claim for damages. The operator of the system must ensure that the
contents of the operating instructions in particular the safety instructions are known to
the operating personnel.
-
It is absolutely necessary to lead the return hose back into the reservoir and securely connect it to
the tank by means of the plug connection 3 and the adapter 2 and / or 1.
The use of non-original accessories, e.g. hose lines and connection nipples, may cause accident
in individual cases. In case of accidents and damage caused by foreign parts, no liability can be
accepted.
Modification or alteration of the system is only permitted after consultation with the manufacturer.
The operational safety of the system is only guaranteed if it is used as intended.
Maintenance, inspection and repair work may only be carried out by qualified specialist personnel
who have gained their knowledge by studying the operating instructions.
Maintenance:
-
During cleaning or maintenance work, always disconnect the pump from the power supply and relieve
pressure on the system by operating the nozzle.
-
-
Regularly check the pressurized parts for any possible damage.
-
Immediately replace defective parts with original parts.:.
Warranty:
If the operating instructions and the intended use of the system are observed, we are liable within the
scope of the statutory warranty.
For warranty claims, please include the invoice of your dealer with date of purchase.
Disposal and environmental protection:
After use has ended, dispose of the device is in accordance with the applicable
statutory regulations in an environmentally friendly manner.
Oil-contaminated parts do not belong in the dustbin!
The applicable regulations for display, installation and operation of systems for handling
substances hazardous to water must be strictly observed by the operator.
(such as e.g. WHG, VawS and TRbF)
6
MATO
GmbH & Co. KG
/ Benzstr. 16-24 / 63165 Mühlheim a. Main / Tel:+49(0)6108-906-0 / Fax:+49(0)6108-906-120
Operating manual
Pressure relief for gear pump