a call has been made, the patient or caregiver can also decide to stop the call
from this device by pressing the green "C" button.
Calling the carer
Short-press the red call button or pull the red cord to call for
assistance (if the patient has fallen). The red light will light up
for 10 seconds.
Stop the notification sound directly from the
CCBR-01 device
Stop the call by short-pressing the green 'RESET" button on the
bathroom button, or stop the notification sound by pressing the
"STOP" button on the CruxCare C2 Pager for about 1 second (see
above important note).
IMPORTANT: This device has a built-in safety feature. It will
transmit multiple signals to the Pager during a timeframe of about 10 seconds.
These repeated signals assure that the call is received on the C2 Pager. During this
time, the alert cannot be stopped on the C2 Pager. It can only be stopped after 10
seconds.
Installation
Mount the device at a suitable height using the supplied mounting material. Test
whether the call button can be easily reached. Adjust the red cord so that the red
hook ends 10 centimetres above the floor.
Power supply: 2 x CR2477 lithium ion battery
Battery life: 3 - 4 years
Dimensions: 8.5 x 8.5 x 6cm
Housing material: ABS
Radio-frequency: 433 MHz
FCCID: WNGWCP-11
Features:
Call & reset buttons
Pull the cord to activate the alert after falling
8