1.2 Possible faults and their elimination
The finding and removing of an electrical fault should always be performed by a professional.
Indication
system won't turn on
unusually low maximum
brightness of light fixture
light fixture double flashes
on start up
light fixture won't turn on or
turns off in colour loop mode
*) Replace a defective fuse with a new fuse of the same type and value.
If your appliance has a different fault or the fault cannot be solved by the above mentioned fault removal me-
thod, contact your dealer or the company that installed the product.
1.3 Maintenance
The appliance does not require any special maintenance. The parts and glass can be easily
cleaned with a damp rag while the system is turned off. We recommend using RAVAK CLEANER
to get rid of old faded stains
.
Do not clean with abrasive materials or aggressive chemicals containing solvents, chlorine, acids or lye.
Do not use any medium that releases vapours which react aggressively with metal parts
(eg hydrochloric acid) in the premises where the appliance is installed.
1.4 Package material disposal
The packaging as well as the product itself after the end of its lifetime should be disposed of in a safe manner
according to applicable law on waste. Please recycle any usable packaging parts such as cardboard, paperbo-
ard or polyester foil.
Fault
system is without power
system is connected
incorrectly
temperature restriction
activated
faulty temperature measuring
incorrectly connected light
fixture
Fault removal
check circuit breaker
check RCD
check fuse*
in control unit
check connection
let the light fixture cool off
check light fixture connection
check connection