AFTER EACH USE
Water should not remain in the unit for long periods of
time. Sediments or minerals can deposit on pump
parts and "freeze" pump action. Follow these
procedures after every use:
1.
Flush detergent siphoning tube by placing the filter
into a pail of clean water while running pressure
washer in low pressure mode. Flush for one to two
minutes.
2.
Shut off engine, turn off water supply, point gun in
a safe direction and squeeze trigger to relieve
trapped pressure, engage
trigger
lock on spray gun
and let engine cool.
WARNING
Keep high pressure hose connected to pump and spray
gun while system is pressurized.
ALWAYS point gun in safe direction and squeeze spray
gun trigger, to release high pressure, every time you stop
engine. Engage trigger lock when not in use.
3.
Disconnect
hose from spray
gun and high
pressure
outlet on pump.
Drain water
from hose,
gun, and nozzle
extension.
Use a rag to wipe off
the hose.
4.
Empty pump of all pumped
liquids by pulling
recoil
handle
about 6 times.
This should
remove
most
liquid in pump.
5.
Coil high pressure
hose and properly
hang it on
hook provided
on accessory
tray.
.
7.
Store unit in a clean, dry area.
If storing for more than 30 days see "Long Term
Storage" on next page.
WARNING
WHEN
STORING
FUEL
OR EQUIPMENT
WITH
FUEL
IN
TANK
Store away from furnaces,
stoves,
water
heaters,
clothes
dryers
or other appliances
that have pilot light or other
ignition
source
because
they can ignite fuel vapors.
WINTER
STORAGE
CAUTION
• Failure
to do so will permanently
damage
your pump
and render
your
unit inoperable.
• Freeze
damage
is not covered
under warranty.
To protect the unit from freezing temperatures:
1.
Follow steps 1-7 in the previous section "After
Each Use".
2.
Use pump saver, available at Sears retail item
71-74403, to treat pump. This minimizes freeze
damage and lubricates pistons and seals.
3.
If pump saver is not available, connect a 3-foot
section of garden hose to water inlet adapter. Pour
RV-antifreeze
(antifreeze without alcohol) into
hose. Pull recoil handle twice. Disconnect 3-foot
hose.
4.
Store unit in a clean, dry area.
2O