NOTICE – Only use original the manufacturer, in order to avoid damages.
Otherwise you risk a decrease in machine performance and an increase
in maintenance work. Check the adherence to the technical specifications
according to the operation manual after each maintenance work.
Maintenance Instruction
Generally, pneumatic machines need little maintenance. If the following rules are observed,
the machine will have the expected long life-time and high reliability. Service life and
performance of the machines are decisively determined by:
The air purity
The lubrication conditions and maintenance
The regular control of the compressed air filter, as well as the regular checking of the
machine with regards to external damages.
Inspection and maintenance can be done by the operator. Disassembly and re-assembly of
the machine have to be executed by qualified staff only. Incorrect assembly can lead to danger
of accident for the operator and to defects on the machine. Additionally to the maintenance of
the pneumatic drive by means of a maintenance unit, respectively oiling via the air connection,
specified before, it is a must to the check the grease in the gear and to refill it, if necessary.
The proper quantity of grease is very important from the point of good lubrication and low
heat generation. The grease quantities listened in the following table must be complied with.
In the crank casing
In the bevel gear
In the spur gear
Gears being not sufficiently greased wear out faster, loose power and stop functioning after
a certain period of time.
Check oil level/ Adjust oil volume
Fig.4
After completing maintenance and repair work and before restarting production make sure
that...
All materials, tools and other equipment which are required for maintenance or repairs have
been removed from the work area of the machine.
Any fluid leaks have been removed.
All safety devices on the machine have proper function.
The oil level was checked, if necessary.
Fixtures of screw connections are tight
Removed container covers, screens or filters were reinstalled
50
Grease
Unscrew locking screw 4. Refill oil, if necessary.
4
Connect to compressed air supply.
Adjust oil volume with adjusting screw 5,
if necessary. Optimum volume at 2-3 air
bubbles.
5
Close filler hole with locking screw 4.
Quantity in grams