water hose into the water inlet port and push inward completely. Follow step
#2 in the diagram. Water hose connection is now complete.
2. Connect the water drainpipe
STEP 1: Remove the tape
A
B
Remove the black water drainage cap (indicated as "A" in above illustration),
then connect the gray drainage pipe. Connect the other end of the drainpipe to
the main water drainage pipe in your house. Note: the white washer included
in the packaging fits between the water inlet port and the white-water tube.
3. Connect the water hose to the faucet of the main water supply system
First, install the supplied water quick-connector to the water faucet by screw
thread. Second, remove the clipper from the water quick-connector, insert the
other end of the water hose into this quick-connector port completely, then re-
install the clipper. The water hose is now connected to the water supply. Note:
The water faucet is supplied by the unit owner and is not included in the unit
assembly.
Important: The water pressure of main water supply system must be at least
0.04-0.6 MPa.
Insert the white washer before
attaching the quick connector
to the water faucet
www.newair.com
STEP 2:Insert the water tube
Then install the
Water inlet port on the
clip back
unit back
Remove the clip first
Insert water tube
inward completely
about 15mm deepth