Function
After the motion detector has been con-
nected and fastened to its wall mount,
the system can be switched ON.
approx. 10 s – max. 15 min
2 – 2000 lx
Two setting options are available after
removing the decorative ring
Switch-off delay (time setting)
(Factory setting: 10 s)
Light ON duration can infinitely varied from
approx. 10 s to a maximum of 15 min
Control dial set to (1) =
shortest time (10 s)
Control dial set to (6) =
longest time (15 min)
The shortest time setting is recommended
when adjusting the detection zone and per-
forming the function test.
Twilight setting
(Factory setting: 2000 lx)
The sensor's response threshold can be
infinitely varied from 2 – 2000 lx
Control dial set to (1) =
daylight operation at approx. 2000 lx
Control dial set to (6) =
night-time operation at approx. 2 lx
The adjusting screw must be turned fully
anti-clockwise when adjusting the detection
zone and performing the function test in
daylight.