DISPLAY CONFIGURATION
Display Programming
The second menu corresponds to display configuration. This, in turn, consists of a routine that varies depending on
the operating mode previously selected during input configuration. In any case, only the related routine will be
displayed each time.
dSP
#1
#2
dECP
PPr
Counter mode (#1)
If selected operating mode is counter (Cont), the displayed routine after pressing ENTER will
be the one on the left.
First thing to configure is decimal point position. After "dECP" indication, decimal point position
is shown at the right end that means no decimal point. Press SHIFT key several times to
dECP
locate decimal point in desired position.
After pressing again ENTER, "FACt" indication is displayed, configurable factor, and then
"1.000" with first of the four digits flashing. This factor can be programmed from 0.001 to
9.999.
0000.
Display will increase according to the programmed multiplying factor. This factor is set to
"1.000" by default, which makes display match the real number of pulses received at the input.
A factor of 0.010 will increase display one count every 100 pulses at the input whereas a factor
FACt
of 2.000 will increase two counts for every pulse at the input.
Pressing again ENTER, display shows "oFFS" and then four digits to introduce desired offset
value. Offset can be programmed from 0000 to 9999.
1.000
Offset value is shown on display after every time a main counter RESET is done.
oFFS
Once offset value is introduced, press ENTER to save changes and to return back to RUN
mode.
0000