APPROVAL - SLC
80
SYNC® tested and approved in accordance with AS/NZS 1270:2002 Standard at Michael & Associates, Inc. USA
Tested according to AS/NZS 1270:2002 (in passive mode, electronics switched off)
Frequency, Hz
Mean Attenuation, dB
Standard Deviation, dB
Mean (-) Std. Dev., dB
Clamping Force: 10.9 N
ATTENUATION DATA
125
250
500
20.9
21.6
28.0
3.5
2.1
2.3
17.4
19.5
25.7
TABLE 1
1000
2000
4000
8000
31.7
37.4
38.8
41.0
2.5
2.6
1.9
5.0
29.2
34.8
36.9
36.0
SLC
80
31 dB
Class 5