Power Supply
+12V
13
Positive Power: Connect the RED wire
(central terminal of the connector) from
the power harness to the Battery's POSITIVE
POLE (+12V) using a 1mm² (17 AWG) wire.
The STM 1003 has an internal resettable
thermal fuse.
GND
14
Negative/Ground: Connect the BLACK wire (external terminal of the connector)
from the power harness to the Battery's NEGATIVE POLE (-), using 1mm² (17 AWG)
wire.
Attention: If you use a 12V source for the STM 1003 that is separate from
the rest of the system, connect all the ground wires attach all ground
connections from the sources together.
REM IN
15
Input for Remote Turn On: The RED wire (center terminal of the connector) from
the remote wire harness can be connected to the remote output of a CD/MP3
Player using a 20 AWG cable, or through an on/off switch on the +12V.
REM OUT
16
Output for Remote Turn On: The BLACK wire (outer terminal of the connector)
of the remote wire harness can be used to power other sound systems from the
remote turn on. Use a 20 AWG cable.