Ermenrich Ping SA20 Stud Detector
EN
Getting started
Open the battery compartment cover (8) and insert a battery according to the correct polarity. Close the cover.
Calibration
Place the device flat against any surface that is free of studs, metal and AC cables. Press and hold the Power/scan button (4) until the red (1) and
green (7) indicators flash and a beeping sound is heard. The calibration is complete when the green light turns on. Do not move the device until
the calibration is complete. Wait for 3 seconds after the calibration is complete before using the device.
Calibration must be done every time the device has been turned on for use.
Usage
Complete the calibration and place the device flat against the examined surface. Press and hold the Power/scan button (4) and slowly move the
detector across the surface in the direction you want to scan. When the device detects the edge of a stud, signal strength indicators (2, 5) light
up. Continue sliding it in the same direction until the signal strength indicators go down. Start slowly moving the device in the opposite direction
until the signal strength indicators (2, 5) light up again. When the device detects the center of a stud, the center indicator (1) lights up.
If you are receiving erratic scanning results, it may be a result of humidity, moisture within the wall cavity or drywall, or recently
applied paint or wallpaper that isn't fully dried.
Low battery indicator
If the battery status indicator (7) starts flashing, immediately change the battery.
Specifications
Max. detection depth
Sound alert
Light alert
Operating temperature range
Power supply
Dimensions
Weight
The manufacturer reserves the right to make changes to the product range and specifications without prior notice.
Care and maintenance
Do not exclusively rely on the detector to locate items behind scanned surfaces. Do not assume that there is no live cabling inside a wall.
Always disconnect the power, gas, and water before scanning. Calibrate the device regularly. Do not try to disassemble the device on your
own for any reason. For repairs and cleaning of any kind, please contact your local specialized service center. Protect the device from
sudden impact and excessive mechanical force. Store the device in a dry cool place. Only use accessories and spare parts for this device that
comply with the technical specifications. Never attempt to operate a damaged device or a device with damaged electrical parts! If a part of
the device or battery is swallowed, seek medical attention immediately. Keep away from children.
Battery safety instructions
Always purchase the correct size and grade of battery most suitable for the intended use. Always replace the whole set of batteries at one
time; taking care not to mix old and new ones, or batteries of different types. Clean the battery contacts and also those of the device prior
to battery installation. Make sure the batteries are installed correctly with regard to polarity (+ and –). Remove batteries from equipment
that is not to be used for an extended period of time. Remove used batteries promptly. Never short-circuit batteries as this may lead to high
temperatures, leakage, or explosion. Never heat batteries in order to revive them. Do not disassemble batteries. Remember to switch off
devices after use. Keep batteries out of the reach of children, to avoid risk of ingestion, suffocation, or poisoning. Utilize used batteries as
prescribed by your country's laws.
Levenhuk International Lifetime Warranty
All Levenhuk telescopes, microscopes, binoculars, and other optical products, except for their accessories, carry a lifetime warranty
against defects in materials and workmanship. A lifetime warranty is a guarantee on the lifetime of the product on the market. All Levenhuk
accessories are warranted to be free of defects in materials and workmanship for six months from the purchase date. The warranty entitles
you to the free repair or replacement of the Levenhuk product in any country where a Levenhuk office is located if all the warranty conditions
are met.
For further details, please visit: www.levenhuk.com/warranty
If warranty problems arise, or if you need assistance in using your product, contact the local Levenhuk branch.
wood/metal studs: 19mm (¾")
+
+
0...+40°C (operating), −10...+50°C (storage) / +32...+104°F (operating),
+14...+122°F (storage)
1pc 9V battery
146x63x35mm (5.7x2.5x1.4in)
90g (0.2lb)