SOUND TOP ENERGY
Epta Spa - Via Mecenate, 86 - 20138 Milano (MI) ITALIA
Tel. 02/55403211 Telefax 02/55401023
Control panel
Controller LAE BR1-28
1
1. "i" key
2. "Defrost & Down" Key
3. "M & Up" Key
Fig. 23
4. "X & Stand-by" Key
5. Led "II"
Function of keys:
• Switching from LT to MT and the other
way around. Press the (3) key, the
display will read Bt (LT) or Tn (MT);
using the (2) key, select the desired
operating mode, Bt (for LT) or Tn (for
MT), then confirm using the (1) key.
(5) ON = MT, (1) OFF = LT.
• Manual defrost. Hold the (2) key down
for 5 secs.
• Buzzer. The buzzer always goes off
when in an alarm condition; press any
key to stop it.
F
Thermostat adjustment is reserved
for
service. The cabinet is factory-
adjusted for correct perfomance.