Overload cut-out
In case it is overloaded, the motor stops. In this case, switch the product off,
remove the mains plug and let it cool down for 10 minutes, then repeat the start-
up procedure as described in below chapter-"operation".
If the problem recurs more than once, contact your authorised service centre.
Safety valve
The safety valve is a pressure limiting valve. When the trigger (8b) is released,
the valve opens and discharges the pressure inside the pump.
Automatic motor start-stop device
The automatic motor start-stop device is operated by the trigger (8b) of the spray
gun (8). When the trigger (8b) is released the dynamic pressure automatically
cuts out the motor. When the trigger (8b) is depressed the automatic drop in
pressure starts the motor and the pressure is restored after a very slight delay.
General operation
1. Check the product, its power cord and plug as well as accessories for damage
before each use. Do not use the product if it is damaged or shows wear.
2. Double check that the accessories and attachments are properly fixed
3. Always hold the spray gun by its handle and gripping surface. Keep the handle
and gripping surface dry and free from lubricant to ensure safe support.
4. Ensure that the air vents are always unobstructed and clear. Clean them if
necessary with a soft brush. Blocked air vents may lead to overheating and
damage the product.
5. Switch the product off immediately if you are disturbed while working by other
people entering the working area. Always let the product come to complete
stop before averting.
6. Do not overwork yourself. Take regular breaks to ensure you can concentrate
on the work and have full control over the product.
MNL_MAC_GB_High pressure cleaner_MPWP2700_V5_200528.indd 27