Descargar Imprimir esta página

Dantherm Master BC 80 Manual De Instrucciones página 10

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
en
►TIMER: If the device is off, it allows
programming the delayed start. You can
choose between one-hour intervals.
►TIMER: If the device is on, it allows
programming the automatic switch-
off. You can choose between one-hour
intervals.
NOTE: When the control panel
display shows the icon "DROP"
(flashing), it means that the tank
is empty and must be refilled to
reactivate the "COOL" function.
►►4.3. SWITCHING OFF:
►4.3.1. Press the ON/OFF button to
switch off the appliance (Fig. 9).
►4.3.2. Empty the tank using the drain
cap (Fig. 11-12-13).
►►5. CLEANING AND
MAINTENANCE
WARNING: BEFORE PERFORMING
ANY MAINTENANCE OR REPAIR,
DISCONNECT THE POWER CABLE
FROM THE MAINS.
DEPENDING ON THE ENVIRONMENT
WHERE THE APPLIANCE IS USED,
DUST, DIRT OR WATER QUALITY CAN
AFFECT THE PERFORMANCE OF THE
UNIT. THEREFORE, CLEANING THE
FOLLOWING COMPONENTS CAN BE
NECESSARY:
►►5.1. TANK:
We recommend changing the water
frequently.
►5.1.1. Switch off the appliance and
remove the plug from the mains (Fig.
9-6).
►5.1.2. Remove the drain plug in order to
empty the tank (Fig. 11-12-13).
►►5.2. FILTERS:
We
recommend
frequently.
Figures and texts of this book are protected by COPYRIGHT.
cleaning
filters
WARNING: Dirty filters can affect
the performance of the appliance.
►5.2.1. Switch off the appliance and
disconnect the plug from the mains (Fig.
9-6).
►5.2.2. Remove the filters upwards (Fig.
14).
►5.2.3. Clean the filters using a mild
detergent and a clean cloth (Fig. 15).
Ensure the filter is fully dry.
►5.2.4. Place the filter back into its
housing (Fig. 16).
►►5.3. WATER CIRCUIT:
►5.3.1. To ensure proper operation of
the cooler, turn off COOL mode a few
minutes before completely switching off
the appliance, in order to avoid stagnant
water.
►5.3.2. Once a month we recommend
performing a complete cycle using
clean water and appropriate disinfection
products, running the cooler outdoors.
IMPORTANT:
-The cooler tank must be emptied and
sanitised periodically depending on the
use.
-The cooling pad surfaces must be pe-
riodically inspected and sanitised de-
pending on the use.
-For sanitation operations, biocidal prod-
ucts that comply with European regula-
tion no. 582/2012 must be used.

Publicidad