ADVANCED PROGRAMMING
To perform ADVANCED programming it is necessary to activate
the programming by following one of the following procedures:
ACTIVATION OF PROGRAMMING
TX-PLUS 1:
•
Press the STOP + UP + DOWN keys
•
When the LED lights up, release all the keys
•
Programming is activated for 30 seconds
TX-PLUS 2:
•
Press the STOP + UP + DOWN keys of the channel to be
programmed
•
When the LED lights up, release all the keys
•
Programming is activated for 30 seconds
TX-PLUS 4:
•
Press and release the key relative to the channel to be
programmed, the LED will light up
•
Press the STOP + UP + DOWN keys, the LED goes off
•
When the LED lights up, release all the keys
•
Programming is activated for 30 seconds
Note: this procedure will be the same for the programming
of all functions and will not be repeated in the following
paragraphs
List of programmable functions:
1. Memorizing the transmitters and selecting the awning / roller
shutter mode
2. Deleting all memorized transmitters
3. Programming of the intervention level of the wind sensor
4. Programming of the sun sensor intervention level
5. Programming the temperature sensor level
TRANSMITTER DATA STORAGE AND
SELECTION OF THE SUNSHADE/ROLL-UP
SHUTTER MODE
m
CAUTION: The data storage of the first transmitter
determines the direction of motion of the motor.
To store a transmitter on a virgin control untit proceed as
follows:
1. Supply power only to the control unit to be programmed
2. Activate the TX-PLUS programming
3. To select the SUNSHADE mode press the UP or DOWN keys
until the led performs n. 1 flash
To select the ROLL-UP SHUTTER mode press the UP or DOWN
keys until the led performs n. 2 flashes.
4. Press the UP+DOWN keys until the motor starts to move in
one direction
5. Release the keys, the motor stops
6. Press the UP or DOWN keys according to the direction in
which the roll-up shutter was moving before it stopped:
- if the roll-up shutter was being raised press the UP key;
direction obtained: the UP key raises the roll-up shutter,
the DOWN key lowers the roll-up shutter
- if the roll-up shutter was being lowered press the DOWN
key; direction obtained: the DOWN key lowers the roll-up
shutter, the UP key raises the roll-up shutter.
7. To exit the programming mode press the STOP key
8. Try to operate the roll-up shutter and verify that it works
according to the logic described above. If the logic is reversed
it is necessary to delete all the codes stored (see "DELETION
OF ALL MEMORIZED TRANSMITTERS") and repeat the steps
above.
To add other remote controls you can also use the "QUICK
MEMORIZATION OF TRANSMITTERS
DELETION OF ALL MEMORIZED
TRANSMITTERS
To delete all codes stored with an TX-PLUS proceed as
follows:
1. Supply power only to the control unit to be programmed
2. Activate the TX-PLUS programming
3. Press the UP or DOWN keys until the led performs n. 3 flashes
4. Press and hold down the UP+DOWN keys until the motor
moves in both directions which confirms the correct deletion
of the codes.
5. Release the keys
6. To exit the programming mode press the STOP key
To delete all codes NOT stored with an TX-PLUS proceed as
follows:
1. Cut the power to the motor on which to delete all the codes
2. Activate the TX-PLUS programming
3. Press the UP or DOWN keys until the led performs n. 3 flashes
4. Press and hold down the UP+DOWN keys
5. Power the motor and wait until the motor moves in both
directions wich confirms the correct deletions of the codes
6. To exit the programming mode press the STOP key
- 11 -