Descargar Imprimir esta página

FILL-RITE NXFM100 Manual De Instalación Y Funcionamiento página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

|
Table of Contents
Compatibility / Specs............................................................................................................ 2
Online Account Setup............................................................................................................ 3
Warnings................................................................................................................................ 3
NFPA Warnings...................................................................................................................... 3
Wireless Warnings................................................................................................................. 3
Hazardous Area Examples..................................................................................................... 4
Site Survey / Where to Install................................................................................................ 4
UL / cUL / CE.......................................................................................................................... 4
Certifications / Approvals...................................................................................................... 4
NXFM100 Wiring................................................................................................................. 4-5
Mounting Dimensions............................................................................................................. 6
NXFM100 Power On & Verification......................................................................................... 6
NXFM150 Wiring................................................................................................................. 6-7
NXFM150 Power On & Verification......................................................................................... 7
Limited Warranty Policy
Fill-Rite warrants the goods manufactured shall be free from defects of
materials and workmanship. Specific warranty details for individual products can
be found at fillrite.com.
Privacy Statement
Fill-Rite is committed to protecting user's privacy. For more information about Fill-Rite
FMS's privacy policy, please review our full terms and conditions at fillrite.com/fms.
NXFM100 Compatibility & Specs
100-240V AC, 50/60Hz, 3600W
Power Requirements
8-50V DC 1500W*
1HP 125V AC
2HP 240V AC
125V AC 30A General Purpose
Pump Control Ratings
240V AC 15A General Purpose
8-50V DC 30FLA/90LRA
8-50V DC 30A General Purpose
H: 8"
Dimensions
W: 11.5"
D: 5.75"
Weather Ratings
NEMA 4X / IP67
-4˚ F to 122˚ F (-20˚ C to 50˚ C) UL Installations
Temperature Ratings
-40˚ F to 140˚ F (-40˚ C to 60˚ C) non-UL Installations
Power Supply: 12V DC, 100mA
Rate: 1:1 to 10,000:1
Speed: 120,000 pulses per minute (2000Hz)
Pulser
Duty Cycle: 50%
Contact: (example: reed switch, contact close)
Open collector: (wiring example: 12V DC, signal, ground)
fillrite.com
FUEL MANAGEMENT SYSTEM
INSTALLATION AND OPERATION MANUAL
Welcome to Fill-Rite
FMS! For tech support call: 833-483-5859
®
NXFM100 Site Controller
This installation guide contains all of the information you need to install your hardware,
create your online account, and begin using the Fill-Rite FMS.
Before beginning physical installation of your Fill-Rite FMS Site Controller, create an
account at fms.fillrite.com and register your device's serial number to your account.
Physical installation cannot be completed without an online account being created.
If you're using Fill-Rite FMS for the first time, we encourage you to run through the
guided account setup by clicking the button in the top left of the Fill-Rite FMS homepage.
This setup will walk you through the creation of your first site, upload drivers and vehicles,
and orient you to the features of the Fill-Rite FMS web portal.
NXFM150 Expansion Module
This installation guide contains all of the information you need to install the Expansion
Module hardware and expand your Fill-Rite FMS system.
The Fill-Rite FMS expansion system works in tandem with an installed Site Controller to
increase the number of pumps you can monitor with Fill-Rite FMS. Ensure that you have
completed installation of a Fill-Rite FMS Site Controller before installing your Expansion
Module. This includes completing online account setup.
If you have any questions or need help with installation, contact your local Fill-Rite FMS
distributor, visit fillrite.com/fms, or call 833-483-5859.
NXFM150 Compatibility & Specs
80-240V AC, 50/60Hz, 1810W
Power Requirements
12V DC 95W
80-240V AC 7.5A
Pump Control Ratings
12V DC 7.5A
H: 12"
Dimensions
W: 15.5"
D: 5.25"
Weather Ratings
NEMA 4X / IP67
-4˚ F to 122˚ F (-20˚ C to 50˚ C) UL Installations
Temperature Ratings
-40˚ F to 140˚ F (-40˚ C to 60˚ C) non-UL Installations
Power Supply: 12V DC, 100mA
Rate: 1:1 to 10,000:1
Speed: 120,000 pulses per minute (2000Hz)
Pulser
Duty Cycle: 50%
Contact: (example: reed switch, contact close)
Open collector: (wiring example: 12V DC, signal, ground)
*
DC requires a Class 2 power source (see page 5)
DC requires a Class 2 power source (see page 5)
††
Ensure NXFM150 DC installations DO NOT exceed 7.5A
††