SLEEP operation
Pressing this button will increase (during cooling operation) or
decrease (during heating operation, applicable models) 1°F/1°C after
30 minutes. The temperature will again increase (cooling) or decrease
(heating) by another 1°F/1°C after an additional 30 minutes. This new
temperature will be maintained for 7 hours before returning to the
originally selected temperature. This ends the Sleep mode and the
unit will continue to operate as originally programmed.
Other Features
MyTemp
This feature can ONLY be activated from the remote control. The remote control serves as a remote
thermostat allowing for the precise temperature control at its location which must be within 26 feet of the
air conditioner. To activate the MyTemp feature, point the remote control towards the unit and press the
MyTemp button. The remote's display will show actual temperature at its location and must be within
26 feet of the air conditioner to work. The remote control will send this signal to the air conditioner every
3 minutes until the MyTemp button is pressed again. If the unit does not receive the MyTemp signal
during any 7 minute interval, the unit will exit the MyTemp mode.
NOTE: This feature is unavailabe under FAN or DRY mode.
AUTO-RESTART
unexpectedly due to a power outage, it will restart with the previously set function
automatically when the power resumes.
WAIT 3 MINUTES BEFORE RESUMING OPERATION
After the unit has stopped, it cannot be restarted until 3 minutes time has elapsed. This is to protect the
unit. Operation will automatically resume after 3 minutes.
AIRFLOW DIRECTION ADJUSTMENT
The louver can be adjusted automatically using the SWING button.
•
When the Power is ON, the louver opens fully.
•
Press the SWING button on the panel or remote controller to initiate the Auto Swing feature. The louver
will swing up and down automatically.
•
Please do not adjust the louver manually.
Remove
the upper
drain plug
Continuous
drain hose
User Manual
WATER DRAINAGE
•
During Dry modes, remove the upper drain plug from the
back of the unit and install the drain connector (5/8" universal
female mender) with 3/4" hose (locally purchased).
For models without drain connector, just attach the drain hose
to the hole. Place the end of the hose directly in the drain area
you're using.
NOTICE
The SLEEP operation feature is
unavailable in FAN or DRY mode.
Page 11