The ambient temperature must not exceed 40°C and ambient humidity should not
exceed 85%. Place the unit in a way that ensures good air circulation. Keep the unit
away from any hot surfaces. Always operate the unit on a level, stable, clean,
fireproof and dry surface and out of the reach of children and persons of impaired
mental, sensory and intellectual functions. Place the unit in such a way that the
mains plug can be reached at any time. Ensure that the power supply to the unit
corresponds to that specified on the identification plate! Due to the fact that the
device may vibrate during operation, it should be well-levelled on the surface on
which it will be used.
3.3.
Working with the device
If the power light (J) lights up after connecting the device to the power
source, it means that everything is OK and the device is ready for
operation.
Before use, select the rollers depending on the thickness of the rod to be
bent. The rollers are disassembled/assembled by unscrewing/tightening
the screws with an "ear" end that are holding them.
IMPORTANT: in the case of the MSW-RC-250D model, the angle for the
first bending step should be at least 5
step.
Use the knob on the guide to adjust its position depending on the
thickness of the bar, so that the bent bar rests not only against the guide,
but also against the stationary bending roller.
o
smaller than the second bending