AC Cable Requirements
Avoid power loss of more than 1% of nominal inverter rating, in cables. The cable cross-sections
specified below are recommended for cable lengths up to 10 m.
Exterior use or use outdoors, weather-resistant
Specification
When selecting cable for the AC installation, ensure to comply with local and national regulations.
Recommended minimum
cable requirements
Jacketed cable (rubber in-
sulation)
Outdoor use
Temperature range
Outdoors ⌀ max.
Table 2.2: AC Cable
Fuses
The main purpose of the fuse is to protect the installation against short circuits. It is recommended
to use a slow fuse, class C. When selecting the fuse for the AC installation, ensure to comply with
local and national regulations.
Specification
Fuse
Current
Voltage
Table 2.3: Recommended fuses
2.1.5. Inverter Autotest - Italy only
An automatic test of the inverter can be initialised by using the Inverter Autotest Software. Please
read the Autotest manual before initialising the software. Software and manual are available free
of charge, please contact your supplier for further information. The software is used in conjunction
with an RS485 to USB converter in order to communicate between inverter and PC. Such a con-
verter can be purchased at any computer retailer.
2.1.6. Start-up
Note:
This is an international inverter. The inverter is approved and certified to run in 16 countries.
The inverter has not had country settings specified. It will not run before this has been done.
Check that all connections have the correct polarity and that cables are securely fastened. Turn
on the AC grid. The display will now prompt for "Language".
Illustration 2.10: Language
TRI-Xi
1.8
H05RN-F3G 2.5
H05RN-F3G 1.5 mm
2
≥500 [V]
-30 - +60°C
-30 - +60°C
10 mm
TRI-Xi
TRI-Xi
1.8
3.6
16A
16A
240V
240V
Press '
es. Select language by pressing 'OK'. The dis-
play will now show "Country" in the language
chosen previously.
L00410352-02
2. Installation and Set-up
TRI-Xi
TRI-Xi
3.6
5.4
H05RN-F3G 4.0 mm
2
mm
≥500 [V]
≥500 [V]
-30 - +60°C
10 mm
10 mm
TRI-Xi
5.4
25A
240V
' to scroll down through the languag-
2
2
11