Bake burner injector (orifice) replacement
1. Remove the drawer from the range cooker.
2. Unscrew the nut on gas tube connection with gas pressure regulator using 9/16 or adjustable
wrench.
3. Unscrew two screws that are holding injector (orifice) holder from the back side of range cooker
base.
4. Remove the gas tube with injector (orifice) holder towards you.
5. Replace the injector (orifice) according to the table of injectors (orifices) using 9/32 or 7 mm nut
driver.
6. Align the gas tube with injector holder back to the gas pressure regulator and tighten it with hand.
7. Screw the injector (orifice) holder back to the range cooker base.
8. Tighten gas tube connection with gas pressure regulator using 9/16 or adjustable wrench.
9. Check gas tightness of the connection of gas tube with gas pressure regulator.
Gas pressure regulator conversion
Cooktop burners injector (orifice) replacement
1. Remove the grates, burner caps and burner heads from all burners.
2. Replace the injector (orifice) according to the table of injectors (orifices) using 9/32 or 7 mm nut
driver.
3. Reassemble burner heads, caps and grates.
Adjusting minimum flow
1. Turn on all top burners and set them on "LO" setting.
2. Remove the knobs and fully tighten the regulation screws using small flat blade screwdriver.
1. Remove the drawer from the range cooker.
2. Unscrew the nut on gas pressure regulator
using _5/8 or adjustable wrench.
3. Remove the protection cap.
4. Turn the metal nut on counter side and
assemble the protection cap back.
5. Screw the nut back to the gas pressure
regulator.
EN 3