TROUBLESHOOTING GUIDE
THE COLUMN HAS NO PRESSURE
Make sure if the flexible connections to the
Ÿ
pipes are not twisted or folded (Pic.1).
Check if the pressure of water heater is not
Ÿ
above or below the recommended.
Make sure it was done the cleaning pipes
Ÿ
before connecting and mounting the column
(Pag. 16).
Check the filters and check valves of the
Ÿ
hydraulic assembly of the column (Pic.2).
Pic.1
THERMOSTATIC REGULATOR
TEMPERATURE IS NOT
CALIBRATED CORRECTLY
A proper calibration of the temperature control
thermostat should be 38 º C.
The regulators of Sanitana thermostatic are
calibrated and checked according norm EN111
Standard regarding the following parameters:
Calibration relates only to a temperature of
Ÿ
38 ºC.
The calibration is performed at a pressure of 3
Ÿ
bar for hot and cold water.
The calibration is carried out using cold water at
Ÿ
15 ° C and hot water at 65 ° C.
If the hydraulic installation that supplies the
showerpanel has different values from those
used in the manufacturing standard calibration it
may be necessary to carry out a new manual
calibration.