17
Owner's Manual
NOTICE: Replace used filters only with a new Legend Brands 4-PRO filter part
no. #100250 (F581) (24-pack). Other filter types do not provide adequate filtration
or airflow. Each filter is individually wrapped to protect filtration effectiveness.
Remove the wrapper before installing the filter into the dehumidifier.
MONTHLY
Inspect coils. Clean when dust accumulation is visible. In normal use, dust can
accumulate and can restrict airflow, reducing performance and causing the unit to
overheat. Use a vacuum cleaner with a brush tool and a soft cloth to remove any
debris. Take care not to damage any interior components.
To maintain appearance, wipe interior and exterior surfaces with a damp cloth. For
deep cleaning and a lasting, protective shine, use an automotive interior cleaner.
AS NEEDED
Clean pump check valve and basin. Remove grills and cover. Remove screws from
pump base and lift out pump. Wipe out pump basin with a damp cloth. Inspect the
pump base for build-up of debris and clean if needed. Unthread barbed fitting with
check valve and rinse fitting and check valve with clean water. Reinstall check valve
into barbed fitting and install the barbed fitting into pump. Do not overtighten.
Reinstall pump on base. Reinstall cover and grills.
Clean coils. With the cover removed, inspect both coils. If excessive dust and debris is
present, vacuum thoroughly and/or clean with coil cleaner.
LGR 7000 XLi Owner's Manual
© 2023 Legend Brands, Inc.