acceptable. When installing vertically, please observe the following preferred enclosure
orientations:
6. Use the base of the charger as a mounting template to mark the positions of the fixing
screws.
Keep a clear space of at least 10 cm around this product for cooling purposes!
2.3
Wiring details
For user safety during installation, please make sure that the output of the supplying source
is switched off (temporary remove fuses from the fuseholders) and that no consumers are
connected to the batteries.
Please double check if the battery voltages match the specifications of the used charger
model.
Always connect ground (- GND) first followed by the service (+ OUT) battery and lastly the
starter (+ IN) battery.
Before connecting the main DC cables, make sure to slide the included rubber grommets
over these cables like shown in the next image.
!
CAUTION
WARNING
!
CAUTION
!
CAUTION
8