6.1
Periodic maintenance
The maintenance activities in the table below indicated by [*]
can be carried out by the user; other activities are strictly
reserved for well trained and authorized service personnel.
Periodic maintenance to be carried out in accordance with
TRGS 560.
Component
Housing
Spark arrester
Main filter
Filter cleaning
mechanism
Dust tray
Extraction fan
Mains cord
6.2
Filter replacement
ATTENTION!
Always wear face mask and gloves during filter
exchange/cleaning.
6.2.1 LongLife main filter
You must learn from experience when to replace the main filter,
since the lifespan of the filter strongly depends on the welding
process, the composition of the welding fumes, the intensity of
use and the humidity.
Replace the main filter:
- when the control light keeps blinking (shortly) after an off-line
cleaning cycle; or
- when the airflow is reduced to the point that extraction
performance is no longer satisfactory; or
- when it has been damaged.
BGIA approved machines only (additional):
Replace the main filter:
- when the buzzer keeps emitting an intermittent acoustic
signal while the cleaning mechanism is in operation.
To replace the main filter proceed as follows.
CAUTION!
Be careful replacing the main filter; it is provided with
a precoat.
Fig. 6.1
Turn off the machine and disconnect it from the mains.
Loosen the thumb nut (A) and remove the filter cover (B).
0507260020/150709/E Mobiflex 400-MS - Mobiflex 400-MS/C
Action
Clean the outside of the machine with a non-aggressive
detergent.
Clean the inside of the machine using an industrial
vacuum cleaner and remove dust from the filter
compartment.
Clean the spark arrester using an industrial vacuum
cleaner.
Check the filter for damage, clogging and saturation.
Replace if necessary.
Check the functioning of the filter cleaning mechanism via
manual operating (turning, leakage).
Inspect the dust tray. Empty if necessary.
Check the extraction fan and the extraction fan housing
for encrusted particles. Clean if necessary.
Check sealing material of the extraction fan. Replace if
necessary.
Check the mains cord for damage. Repair or replace if
necessary.
WARNING!
It is not allowed to clean any filter by blowing,
shaking, etc.
1-3
months
X [*]
X [*]
Before every
X [*]
use
A
B
Fig. 6.1: Open filter cover
Fig. 6.2
Lift the main filter (A) up and out of the housing.
Pack the used main filter in the plastic bag in which the new
filter is supplied. Seal the bag firmly.
Clean the spark arrester (B) and filter compartment (C) with
an industrial vacuum cleaner.
Place a new LongLife main filter.
Mount the dismounted parts in reverse order.
Frequency
Every 3
Every 6
Every 12
months
months
months
X [*]
X [*]
X [*]
X
X
X
C
EN - 16