PULMIC PEGASUS 35
MOTOR & PUMP
The motor, the pump and the pressure switch
are sensitive items subject to wear, they are
integrated into a single module and need
preventive maintenance to extend their useful life.
To keep the pump head in proper operating
condition after each application, run the sprayer
with clean water in open circuit for a few minutes.
Never let the pump with phytosanitaries inside over 8 hours, these products
may precipitate or agglutinate causing clogging and malfunction thereof.
Furthermore, if such products contain significant concentrations of organic
solvents or solvents will damage the internal elements thereof.
Do not use any corrosive acid, and if you do so by accident, immediately
clean the tank and clean the circuit with clean water in open circuit circulating
it for some time.
To preserve the motor, do not immerse the sprayer in any type of liquid and
protect it from moisture as much as possible. This motor is a DC brushed
motor, its wear and useful life will depend exclusively on the aforementioned,
the ambient temperature and the average working pressure.
Watch the product maintenance video through the following link
or QR:
www.tiny.cc/peg35-05-en
www.gruposanz.es
— 14 —
PULMIC PEGASUS 35
6. PROBLEMS AND SOLUTIONS
PROBLEM
POSSIBLE CAUSE
Battery is not charged.
Sprayer doesn't turn on.
Loose wire.
Hose(s) have a loose
Leaks from tank area.
connection with the
pump or tank.
Loosen or damaged
seals.
Leaks from lance or
Ball valve inside the
nozzle areas.
handle is worn or some
dirty prevents proper
closing.
Tank / pump / hose /
Clogged pump / hose /
gun / nozzle(s) hasn't
gun / wand / nozzle.
been properly rinsed
with cleaning solution or
water after use.
Wear or breakage of
Broken parts.
parts.
Defective or poorly
adjusted pump pressure
The pump works
switch.
continuously and does
not stop when spraying
The filters are dirty, or
the nozzle is clogged.
stops.
An unsuitable nozzle is
being used.
Watch the videos of the main repairs through the
following link or QR:
www.tiny.cc/peg35-06-en
www.gruposanz.es
SOLUTION
Recharge battery.
Ask for technical support.
Remove screws and plastic
covering to expose pump.
Check for loosen clamps
on both hoses.
Check all the seals. Tighten
or replace if neccesary.
Ask for technical support.
Rinse sprayer thoroughly
with warm, soapy water
after each use.
Replace with proper spare
parts. Or ask for technical
support.
Ask for technical support.
Clean filters and pipes,
as well as the nozzle. Or
replace the nozzle with one
suitable for this sprayer.
— 15 —