Descargar Imprimir esta página

Steinberg Systems SBS-KW-3TE Instrucciones De Uso página 15

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
KEYPAD OPERATION
The keypad includes those keys such as ON/OFF, HOLD, SWITCH, ZERO.
(Note: the above keys can be used in sub-menu to set up Kg-lb conversion, Hold,
Beeper On/Off, Zeroing and backlighting, etc.)
Model
Max. Capacity (kg)
SBS-KW-3
3000
SBS-KW-5
5000
SBS-KW-10
10000
1. [HOLD]
: Press this key to keep the current weight and there is a LED
Modell
Max. Beladung (kg)
indication lamp on the bottom of the display window.
SBS-KW-3
3000
SBS-KW-5
5000
Press this key again when the displaying weight flickers
SBS-KW-10
10000
to cancel the HOLD function.
2. [SWITCH]: Press this key to change between Measured Division
and Hi resolution Division.
3. [ZERO]
: Press this key to set the current weight to zero.
GENERAL SCALE OPERATION
EN
1.
Turn On the Scale
Press the power switch located under the displaying window of scale. The scale's
maximum weighing capacity is first shown, and then the scale goes through a
self-check sequence. 5 seconds later, the scale will stabilize and be ready for op-
eration. (Note: it is recommended to allow scale 3~5 minutes of warm-up time
before starting weighing operation).
2.
Zeroing
In general, the scale shows "0.0kg" or "0.00kg" after it is turned on. In case the
display is showing numerical value other than "0", press [ZERO] on the keypad or
the remote to set the display to "0".
3.
Weight Measurement
a) Once the load is suspended completely, the display shows the weight value of
the load. When the "Stable" indicator is lit, weight value can be recorded.
b) In case there is tare such as cable, load the tare and press [ZERO] to zero the
display to "0"kg. The weight value after this will be the net weight. This will not
change until the tare change or the scale being turned off.
4.
Turn Off the Scale
After weighing operation, press the power switch to shut off the power completely
to prevent the leakage of the battery.
Min. Load (kg)
Measured
Division Hi
Division
resolution
20
1
0,5
40
2
1
100
5
2
Min. Beladung (kg)
Genauigkeit
Wahlweise
20
1
0,5
40
2
1
100
5
2
23
BATTERY CHARGING
The scale adopts maintenance-free rechargeable battery and smart charger.
a. The LOB indicator will be on if there is low power. The battery needs to be
charged now. The scale, however, can continue to operate for about
5 hours without charging.
b. After the LOB indicator is ON for several hours without charging or there
is no more power in the battery, the scale will be powered off automatically.
c. After battery charging, if there is no display, it indicates that either there
is difficulty in battery charging or a damaged battery. Please contact
supplier for repair or replacement.
To prolong the battery life, we suggest you charge the battery after using 48hours
or no less than once per week. To avoid any damage to the battery, please charge
it correctly. Additionally, we suggest you switch off the scale to short the charging
time. The charging lamp on the displaying window and adaptor will turn to be red
during charging. When the charging lamp on the adaptor becomes green, it me-
ans the battery is fully charged.
PRECAUTION
1. Please charge the scale with standard charger.
2. The load placed on the scale hook must not exceed the maximum weighing
capacity of the scale.
3. Perform routine inspection and maintenance to ensure operation safety for
these basic items:
a)
Check for loose bolts.
b)
Check hook and shackle for deformation, wearing and tearing.
c)
Check other scale component for signs of metal fatigue.
d)
Check for missing hook latch.
e)
Avoid hitting, bumping the display window.
f)
Do not use the scale in the rain or heavily polluted environment.
g)
If the scale is not going to be used for some time, please clean it,
remove the battery and store it in dry conditions.
For problem "a" through "d", please stop using the scale and send it back to your
supplier for repair or replacement of problem parts.
24
EN

Publicidad

loading

Este manual también es adecuado para:

Sbs-kw-5teSbs-kw-10teSbs-kw-3tcSbs-kw-5tcSbs-kw-10tc