Descargar Imprimir esta página

Legend Brands Dri-Eaz LGR 2800i Manual De Instrucciones página 14

Ocultar thumbs Ver también para Dri-Eaz LGR 2800i:

Publicidad

Idiomas disponibles

Idiomas disponibles

Owner's Manual
CONTROL PANEL
MESSAGE
ER4 Error
Defrost Thermistor Con
nect
—or—
ER4 Error
Outlet Thermistor Conn
ER5 Error
Inlet RH1 Temp/RH Sen
ER6 Error
Current Sensor Failure
ER9 Error
Pump Blocked
Low BATTERY
BLE Error
Flash Reset
WDT Reset
LGR 2800i LGR 3500i Owner's Manual
Temp sensor is open, missing, or shorted. Check that
temp sensors are installed correctly on control panel.
If error persists, contact service.
ect
Inlet Temp/RH sensor is open, missing, or shorted.
Check that inlet temp/RH sensor is installed correctly
on control panel and inlet shroud. If error persists,
sor
contact service.
Current sensor failure. If error persists, contact
service.
Check for obstructions in drain hose. Check the
pump.
W1
Replace coin cell battery (3V, CR2032) on control
panel.
W2
W3
Cycle power to dehumidifier. If warning persists,
contact service.
W4
EXPLANATION AND SOLUTION
14
© 2023 Legend Brands, Inc.

Publicidad