InstAllAtIon
Installation must be carried out in compliance with current standards and
regulations. Installation must be only be carried out by specialized and licensed
personnel.
Identification plate
The identification plate is located on the left-hand side next to the operating dial.
Cabinet requirements
If fitting in flammable material, the guidelines and standards for low voltage
Z
Z
installations and for the fire protection must be strictly observed.
For fitted units, the components (plastic materials and veneered wood) must be
assembled with heat-resistant adhesives (max. 100°C): Unsuitable materials and
adhesives can result in warping and detachment.
The cabinet must allow sufficient room for the electrical connections of the warming
drawer. The cabinet must be sturdy enough to withstand the weight of the warming
drawer. The warming drawer must be securely installed in the recess. The warming
drawer can be installed in a column housing unit or below the countertop of a
modular unit, provided sufficient ventilation is guaranteed.
Electrical connection
FRANKE warming drawer are supplied with a power cable and a Schuko plug.
Make sure the characteristics of the household electrical system (voltage,
X
Z
maximum power and current) are compatible with those of the warming drawer.
If the warming drawer is to be permanently connected to the power supply:
Install a device that enables disconnection from the power supply, with a contact
X
Z
opening distance (3 mm) that ensures complete disconnection in category III
overvoltage conditions.
Ensure the following:
X
Z
– The plug and socket are suitable for a 16 A current.
– The plug and the socket can be easily reached and are positioned so that no live
part is accessible when inserting or removing the plug.
– The warming drawer does not rest against the plug when installed in the cabinet.
– A 3 x 1.5 mm
H05V2V2-F type cable is used when replacing the power cable.
2