Orbegozo ADR 91 Manual De Usuario página 29

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MANUAL USUARIO ADR 91
2. Push the Exhaust hose into the airoutlet opening along the the arrow direction. The duct can
be compressed or extended moderately according to the installation requirement, but it is
desirable to keep the duct length to a minimum.
CAUTION: Make sure that there is no obstacle around the air outlet of the exhaust hose (in the
range of 500mm) in order to the exhaust system works properly.
Water drainage
During dehumidifying modes, remove the drain plug from the back of the unit, install the drain
connector (5/8 universal female mender) with 3/4 hose (locally purchased). For the models without
drain connector, just attach the drain hose to the hole. Place the open end of the hose directly over
the drain area in your basement floor.
When the water level of the bottom tray reaches a predetermined level, the unit beeps 8 times, the
digital display area shows "P1". At this time the air conditioning/dehumidification process will
immediately stop. However, the fan motor will continue to operate (this is normal).
Carefully move the unit to a drain location, remove the bottom drain plug and let the water drain
away. Re-install the bottom drain plug and Restart the machine until the "P1" symbol disappears. If
the error repeats, call for service.
29