Register your product online!
Use your smartphone camera
to scan the QR code or visit our
website totalpond.com/register
Before installing your pump please write down the following
The 14 digit serial number located on the pump
___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___
Item number:
Date of purchase:
______
___ /___ /___
MAINTENANCE & TROUBLESHOOTING
Always disconnect units from the power source before
beginning any maintenance or work on the unit.
• The filter may require cleaning from time to time for optimal
performance.
• The exterior surface of the filter box may need occasional
cleaning. Particularly if the openings in the top of the filter
box are obstructed. When cleaning the filter box use warm
water only. Do not use any chemicals that may destroy the
beneficial bacteria.
• Remove the filter pads and clean with water and when
they are visibly soiled. For best results, clean the filter pads
weekly.
• Filter pads should be replaced annually or when visibly
deteriorating. Use Replacement Filter Pads #52233.
8
Visit WWW.TOTALPOND.COM for information and tips.
information:
Pump date code:
____ /____
mm
yy
00000000000000
item number
FILTER
• The bioballs contain beneficial bacteria. At least once a
year the entire system should be disassembled and cleaned
thoroughly using warm water. This should not be done during
the warm season as it may take up to 8 weeks to re-establish
the environmental balance. The best time of the year to
"breakdown" your system is in early spring before the water
temperatures begin to rise.
• Put all media back into the filter and reconnect the pump to
the power source when you are finished.
PUMP
Regular cleaning of the pump may be necessary depending
upon the environment in which it is operated. Clean the pump
when it is visibly soiled or when a drop in performance is
detected.
Step 1. Before cleaning, always
disconnect the pump from the
power source and remove the
pump cover.
Step 2. Remove the impeller
cover to expose the impeller
assembly. Remove the impeller
assembly by gently pulling
on the impeller blades. The
impeller is held in place by a
magnet.
Step 3. Use a soft cloth or brush
and warm water to clean the
impeller and the inside of the
impeller housing.
Step 4. Reassemble all pump parts and place in water before
reconnecting to the power source.
TROUBLESHOOTING
IF THE PUMP FAILS TO OPERATE:
• Check to make sure the power cord is plugged in and the pump
is getting power.
• Check the pump outlet and any tubing, fountains, spitters etc.
for kinks or obstructions.
• Remove the front cover and/or pump cover, and impeller cover
to expose the impeller. Turn the impeller to ensure that it is not
broken or jammed.
Please call Customer Care before returning item to store: 1-888-412-6001
1
2
3
4
9